Directions
- Remove timer and coin mechanism from parking meter. This will eliminate the paint and ink from being removed from the other surfaces.
- Place in main tank filled at least 2/3 full with #222 Non-Ammoniated Ultrasonic Cleaning Solution or a heated solution of SF-50 Solvent-Free Degreaser.
- Place pan into main tank and cavitate 10 minutes.
- If SF-50 Solvent-Free Degreaser is used rinse parts with warm water and then go to step 5 to ensure complete displacement of water.
- Remove from main tank and place into Auxiliary Pan containing Instrument Rinsing Solution.
- Cavitate for 10 minutes.
- The timer should be disassembled and the main arbor and gears should be properly lubricated according to the manufacturer’s recommendation.